As·ev

Products

MYPTJ

The conductor of the flexible rubber‑sheathed mobile mining cable typically consists of several strands of fine copper wires. The insulation material is an ethylene‑propylene rubber compound, while the sheath material is a flame‑retardant chlorinated polyethylene blend. Different shielding structures and sheath colors are employed depending on the voltage levels. This cable is primarily used for electrical connections in underground mobile mining equipment, for connecting cutting machines and similar devices, for linking underground frequency‑conversion units, as well as for interfacing with mobile frequency converters installed underground, among other applications. The conductor of the flexible rubber‑sheathed mobile mining cable typically consists of several strands of fine copper wires. The insulation material is an ethylene‑propylene rubber compound, while the sheath material is a flame‑retardant chlorinated polyethylene blend. Different shielding structures and sheath colors are employed depending on the voltage levels. Purpose >>Mobile rubber-sheathed flexible cable for coal minesPower connection of mobile coal mining equipment both above and below the mine shaftThe mobile shielded rubber sheathed flexible cable used in coal mines is used for power connection of mobile coal mining equipment both above and below the mine shaft.Mobile metal-shielded rubber-sheathed flexible cable for coal minesPower connection for mobile coal mining equipment in and under the mineMobile metal-shielded monitoring rubber-sheathed flexible cable for coal minesPower connection of mobile coal mining equipment both above and below the mine shaftPower connection of rubber-sheathed cables for electric drills used in coal mines, connecting mobile coal mining equipment both above and below the mine shaftMobile light rubber-sheathed flexible cable for coal minesPower connection of mobile coal mining equipment in and under the wellRubber-sheathed flexible cable for coal cutterPower connection for coal cutters and similar equipment with rated voltage of 0.38/0.66kVCoal cutter shielded rubber sheathed flexible cablePower connection of coal cutters and similar equipmentMetal-shielded rubber-sheathed flexible cable for coal cuttersPower connection for coal miners and similar equipment.Coal mine electric drill shielded rubber-sheathed cableShenzhou CableLighting for underground coal mine tunnels, interlocking of conveyors, and power connection for control and signaling equipment Model and specification >>Mobile rubber-sheathed flexible cable for coal minesmodelspecificationMY1 core: 4~1853+1 core power cable, core size 4~185; grounding core size 4~50execution standardMT 818.5-2009Mobile shielded rubber sheathed flexible cable for coal minesmodelspecificationexecution standardMYPMYP 0.38/10.66kV, 0.66/1.14kV: 3+1 cores: power core 4~185; ground core 4~50 MYP 3.6/6kV: 3+1 cores: power core 16~150; ground core 16~50MT818.5-2009MT818.7-2009Mobile metal-shielded rubber-sheathed flexible cable for coal minesmodelspecificationMYPTMYPT 1.9/3.3kV:3+1 core: power core 35~150; ground core 35/3~50/3, Shenzhou Shenlan MYPT 3.6/6kV, 6/10kV:3+1 core: power line core 16~150; ground wire core 35/3~50/3execution standardMT818.7-2009Mobile metal-shielded monitoring rubber-sheathed flexible cable for coal minesmodelspecificationexecution standardMYPTJMYPTJ3.6/6kV3+3+3 cores: power core 25~150; ground core 35/3~50/3; monitoring core: 2.5MYPTJ6/10kV. 8.7/10kV:3+3+3 cores: power line core 25~185; ground wire core 35/3~50/3; monitoring line core: 2.5MT 818.7-2009Rubber-sheathed cable for electric drills used in coal minesmodelspecificationexecution standardMZ3+1 cores, 3+1+1 cores: power core 2.5~4; ground core 2.5~4MT 818.8-2009Mobile light rubber-sheathed flexible cable for coal minesmodelspecificationexecution standardMYQ2, 3, 4, 7, 12 cores: 1~2.5MT &18 8-2009Rubber-sheathed flexible cable for coal mining machinemodelspecificationexecution standardMC3+1 core: power core 16~120: ground core 4~25MT 818.2-2009Sheath shielding flexible cable for coal mining machinemodelspecificationexecution standardMCPMCP_0.38/0.66kV• 3+1 core. Power core 16~120: Ground core 4~25MCP-0.66/1.14kV MCP-1.9/3.3kV: 3+1 cores: power core 16~150;Ground wire core 4~35MT 818.2-2009modelspecificationexecution standardMetal-shielded rubber-sheathed flexible cable for coal mining machinesMCPT, MCPTJMCPT (MCPTJ)-0.66/1.14kV: 3+1+1 cores: power core 4~185;Ground wire core 4~70: Control wire core: 1.5~10MCPT-(MCPTJ)1.9/3.3kV: 3+1+1 core: power core 16~150;Ground wire core: 16~70; Control wire core: 2.5~10MT 818.4-2009modelspecificationexecution standardShielded rubber-sheathed cable for electric drills in coal minesMZP3+1 core, 3+1+1 core: power core 2.5~4; ground core 2.5~4MT 818.8-2009 Usage characteristics• Mobile rubber-sheathed flexible cable for coal minesRated voltage: 0.38/0.66kV; the minimum bending radius of the cable is 6 times the cable diameter; the ground wire should be well g

MYJV22

It is primarily used for the electrical connection of underground mobile mining equipment, for connecting shearer cables and similar devices, for interfacing underground frequency converters, and for connecting mobile frequency converters installed underground.The conductors of mining power cables typically consist of multiple strands of thick copper wires; the insulation material is an ethylene‑propylene rubber compound, while the jacket is made from a flame‑retardant chlorinated polyethylene blend. Furthermore, shielding structures and jacket colors are selected according to voltage levels.Purpose>Polyvinyl chloride insulated power cable for coal mines with rated voltage of 1.8/3kV and belowThis product is a fixed-laying cable for coal mines with a rated voltage of 1KV and below, suitable for power transmission in coal mine shaftsCoal mine-used XLPE insulated power cable with rated voltage of 8.7/10 kV and belowThe wooden product is a fixed-laying cable with a rated voltage of 10KV or below for use in coal mines, specifically for power transmission underground.Model and specificationPVC insulated power cable for coal mines with rated voltage of 1.8/3kV and belowmodelSpecification range (mmz)execution standardMVV. MVV22. MVV32. MVV420.6/1kVMVV. MVV223, 3+1#: 4~300 ;0.6/1 kV MVV, MVV224t: 4~185 ;1.8/3KV MVV. MVV223, 3+1€: 10 ~ 3001.8/3kV MVV. MVV224t: 10 ~ 185 ;MT 818.11-2009. MT 818.12-2009》Cross-linked polyethylene insulated power cables for coal mines with rated voltage of 8.7/10kV and belowmodelSpecification range (mm2)Implement standardsMYJV. MYJV22, MYJV32, MYJV420.6/1kVMYJV. MYJV223, 3+1: 4~3000.6/1kV MYJV. MYJV22 4t: 4~ 185 :0.6/1kV MYJV32, MYJV423+1: 4~300 :0.6/1kV. 1.8/3kV MYJV323t: 16 ~ 300 :0.6/1kV -• 1.8/3kV MYJV423: 50 ~ 3001.8/3KV MYJV. MYJV22 3, 3+1#: 10 ~ 300 ;1.8/3KV MYJV. MYJV224: 10 ~ 185 ;1.8/3kV MYJV32. MYJV42 3+1#: 10 ~ 300 :3.6/6, 6/6, 8.7/10kV MYJV, MYJV22,MYJV32 • 25 ~ 300. MYJV42 • 50 ~ 300MT 818.11-2009, MT 818.12-2009Usage characteristics• PVC insulated power cables for coal mines with rated voltages of 1.8/3kV and belowRated voltage: 0.6/1kV, 1.8/3kVThe maximum rated operating temperature of the cable conductor is 70°C.During a short circuit (with a maximum duration of no more than 5 seconds), the maximum temperature of the cable conductor does not exceed 160°CThe ambient temperature during cable laying should not be lower than 0°C, and the minimum bending radius should be 15 times the diameter of the cable.• Cross-linked polyethylene insulated power cables for coal mines with rated voltages of 8.7/10kV and belowRated voltage: 0.6/1kV, 1.8/3 kV, 3.6/16kV, 6/10kV, 8.7/10kVThe maximum rated operating temperature of the cable conductor is 90°C.During a short circuit (with a maximum duration not exceeding 5 seconds), the maximum temperature of the cable conductor does not exceed 250°C.The ambient temperature during cable laying should not be lower than 0°C, and the minimum bending radius should be 15 times the diameter of the cable Cable structure diagram1. Conductor2. Insulating layer3. Filling4. Sheath5. Inner lining layer6. Armor 

MY

Mining cables are generally classified into flexible rubber‑sheathed cables for mobile equipment and fixed‑installation power cables. The main types of rubber‑sheathed mining cables include: MY, MYP, MCP, MCPT, MCPTJ, MVFP, MVFPT, and MYPTJ. They are primarily used for the electrical connection of underground mobile mining equipment, for connecting cutters and similar machinery, as well as for linking frequency converters installed underground, or for connecting portable underground frequency converters, among other applications. The conductor in flexible rubber‑sheathed mining cables typically consists of multiple strands of fine copper wires. The insulation material is an ethylene–propylene rubber compound, while the sheath is made from a flame‑retardant chlorinated polyethylene blend. Different shielding structures and sheath colors are employed depending on the voltage levels.  Purpose >• Mobile rubber-sheathed flexible cable for coal minesPower connection for mobile coal mining equipment both above and below the mine shaft.• Mobile shielded rubber sheathed flexible cable for coal minesPower connection for mobile coal mining equipment both above and below the mine shaft.• Mobile metal-shielded rubber-sheathed flexible cable for coal minesPower connection of mobile coal mining equipment both above and below the mine shaft• Mobile metal-shielded monitoring rubber-sheathed flexible cable for coal minesPower connection of mobile coal mining equipment both above and below the mine shaft• Rubber-sheathed cable for electric drills used in coal minesPower connection for mobile coal mining equipment both above and below the mine shaft.• Mobile light rubber-sheathed flexible cable for coal minesPower connection for mobile coal mining equipment both above and below the mine shaft.• Rubber-sheathed flexible cable for coal cuttersPower connection for coal cutters and similar equipment with a rated voltage of 0.38/0.66 kV.• Sheathed flexible cable for coal cutterPower connection for coal cutters and similar equipment.• Metal-shielded rubber-sheathed flexible cable for coal cuttersPower connection of coal cutters and similar equipment• Shielded rubber-sheathed cable for electric drills in coal minesLighting for underground tunnels in coal mines, interlocking of conveyors, and power connection for control and signaling equipment. Model and specification>>Mobile rubber-sheathed flexible cable for coal minesModel MYSpecification: 1 core: 4~1853+1 core: power line core 4~185; ground wire core 4~50Executive standard: MT 818.5-2009Mobile shielded rubber sheathed flexible cable for coal minesModel MYPSpecifications: MYP0.38/0.66kV, 0.66/1.14kV:3+1 cores: power core 4~185; ground core 4~50MYP 3.6/6kV:3+1 core: power core 16~150: ground core 16~50Executive standards: MT 818.5-2009, MT 818.7-2009Mobile metal-shielded rubber-sheathed flexible cable for coal minesModel MYPTSpecification MYPT 1.9/3.3kV:3+1 core: power core 35~150; ground core 35/3~50/3MYPT 3.6/6kV. 6/10kV:3+1 core: power core 16~150; ground core 35/3~50/3Implement the standard MT 818.7-2009Mobile metal-shielded monitoring rubber-sheathed flexible cable for coal minesModel MYPTJSpecification MYPTJ3.6/6kV:3+3+3 cores: power core 25~150; ground core 35/3~50/3; monitoring core: 2.5MYPTJ6/10kV. 8.7/10kV:3+3+3 cores: power core 25~185; ground core 35/3~50/3; monitoring core: 2.5Implement the standard MT 818.7-2009Rubber-sheathed cable for electric drills used in coal minesModel: MZSpecifications: 3+1 cores, 3+1+1 cores: power core 2.5~4; ground core 2.5~4Implement the standard MT 818.8-2009Mobile light rubber-sheathed flexible cable for coal minesModel MYQSpecifications 2, 3, 4, 7, 12€: 1~2.5Implementing standard MT 818.8-2009Rubber-sheathed flexible cable for coal cutterModel MCSpecification 3+1 core: power core 16~120; ground core 4~25Implement the standard MT 818.2-2009Coal cutter shielded rubber sheathed flexible cableModel MCPSpecification MCP-0.38/0.66kV: 3+1 cores: power core 16~120: ground core 4~25MCP-0.66/1.14kV MCP-1.9/3.3kV: 3+1 cores: power core 16~150Ground wire core 4~35Follow the standard MT 818.2-2009Metal-shielded rubber-sheathed flexible cable for coal cuttersModels MCPT, MCPTJSpecification MCPT (MCPTJ)-0.66/1.14kV: 3+1+1 cores: power core 4~185;Ground wire core 4~70: Control wire core: 1.5~10MCPT-(MCPTJ)1.9/3.3kV: 3+1+1 cores: power core 16~150;Ground wire core: 16~70; Control wire core: 2.5~10Implement the standard MT 818.4-2009Shielded rubber-sheathed cable for electric drills in coal minesModel MZPSpecifications: 3+1 cores, 3+1+1 cores: power core 2.5~4; ground core 2.5~4Implement the standard MT 818 8-2009 Usage characteristics• Mobile rubber-sheathed flexible cable for coal minesRated voltage: 0.38/0.66kV; the minimum bending radius of the cable is 6 times the cable diameter; the ground wire should be well grounded.• Mobile shielded rubber sheathed flexible cable for coal minesRated voltage: 0.38/0.66 kV, 0.66/1.14 kV, 3.6/6 kV: The minimum bend

MYP

Mining cables are generally divided into flexible rubber‑sheathed cables for mobile equipment and fixed‑installation power cables. The main types of rubber‑sheathed mining cables include: MY, MYP, MCP, MCPT, MCPTJ, MVFP, MVFPT, and MYPTJ. They are primarily used for the electrical connection of underground mobile mining equipment, for connecting cutters and similar machinery, as well as for linking frequency converters installed underground, or for connecting portable underground frequency converters, among other applications. The conductor in flexible rubber‑sheathed mining cables typically consists of multiple strands of fine copper wires. The insulation material is an ethylene–propylene rubber compound, while the sheath is made from a flame‑retardant chlorinated polyethylene blend. Different shielding structures and sheath colors are employed depending on the voltage levels.  Purpose >• Mobile rubber-sheathed flexible cable for coal minesPower connection for mobile coal mining equipment both above and below the mine shaft.• Mobile shielded rubber-sheathed flexible cable for coal minesPower connection for mobile coal mining equipment both above and below the mine shaft.• Mobile metal-shielded rubber-sheathed flexible cable for coal minesPower connection of mobile coal mining equipment both above and below the mine shaft• Mobile metal-shielded monitoring rubber-sheathed flexible cable for coal minesPower connection of mobile coal mining equipment both above and below the mine shaft• Rubber-sheathed cable for electric drills in coal minesPower connection for mobile coal mining equipment both above and below the mine shaft.• Mobile light rubber-sheathed flexible cable for coal minesPower connection for mobile coal mining equipment both above and below the mine shaft.• Rubber-sheathed flexible cable for coal cutterPower connection for coal cutters and similar equipment with a rated voltage of 0.38/0.66 kV.• Sheathed flexible cable for coal cutterPower connection for coal cutters and similar equipment.• Metal-shielded rubber-sheathed flexible cable for coal cuttersPower connection of coal cutters and similar equipment• Shielded rubber-sheathed cable for electric drills in coal minesLighting for underground coal mine tunnels, interlocking of conveyors, and power connection for control and signaling equipment. Mobile rubber-sheathed flexible cable for coal minesModel MYSpecification: 1 core: 4~1853+1 core: power line core 4~185: ground wire core 4~50Implement the standard MT 818.5-2009Mobile shielded rubber sheathed flexible cable for coal minesModel MYPSpecification: MYP0.38/0.66, 0.66/1.14kV3+1 core: power line core 4~185; ground wire core 4-~50MYP 3.6/6 kV3+1 core: power core 16~150, ground core 16~50Implement standards MT818.5-2009 and MT818.7-2009Mobile metal-shielded rubber-sheathed flexible cable for coal minesModel MYPTSpecification MYPT 1.9/3.3kV3+1 core • power core 35~150 • ground core 35/3~50/MYPT3.6/6kV 6/10kV.3+1 core • Power core 16~150 • Ground core 35/3~50/3Implement standard MT 818.7-2009Mobile metal-shielded monitoring rubber-sheathed flexible cable for coal minesModel MYPTJSpecification MYPTJ3.6/6kV:3+3+3 cores: power core 25~150; ground core 35/3~50/3; monitoring core: 2.5MYPTJ6/10kV.8.7/10kV3+3+3 cores: power core 25~185; ground core 35/3~50/3; monitoring core: 2.5Implement the standard MT 818.7-2009Rubber-sheathed cable for electric drills used in coal minesModel MZSpecifications: 3+1 core, 3+1+1 core: power core 2.5~4, ground core 2.5~4Implement the standard MT818.8-2009Mobile light rubber-sheathed flexible cable for coal minesModel MYQSpecification: 2.3.4.7. 12-core, 1~2.5Implement standard MT 818.8-2009Rubber-sheathed flexible cable for coal cutterModel MCSpecification 3+1 core: power core 16~120; ground core 4~25Implement standard MT 818.2-2009Coal cutter shielded rubber sheathed flexible cableModel MCPSpecification MCP-0.38/0.66kV 3+1 core: power core 16~120; ground core 4~25MCP-0.66/1.14KV MCP-1.9/3.3kV: 3+1 cores: power core 16~150Ground wire core 4~35Implement the standard MT8189-2009Metal-shielded rubber-sheathed flexible cable for coal cuttersModels MCPT, MCPTJSpecification MCPT (MCPTJ)-0.66/1.14kV: 3+1+1 cores: power core 4~185Ground wire core: 4~70; Control wire core: 1.5~10MCPT-(MCPTJ)1.9/3.3kV: 3+1+1 cores: power core 16~150Ground wire core: 16~70; Control wire core: 2.5~10Implement standard MT 818.4-2009Shielded rubber-sheathed cable for electric drills in coal minesModel MZPSpecifications: 3+1 core, 3+1+1 core: power core 2.5~4; ground core 2.5~4Implement standard MT 818.8-200 Usage characteristics• Mobile rubber-sheathed flexible cable for coal minesRated voltage: 0.38/0.66kV; the minimum bending radius of the cable is 6 times the cable diameter; the ground wire should be well grounded.• Mobile shielded rubber sheathed flexible cable for coal minesRated voltage: 0.38/0.66 kV, 0.66/1.14 kV, 3.6/6 kV: The minimum bending radius of the cable is the cable diameter6 times the d

< 1 > proceed page

Get a Quote

Your consultation will help us provide you with the most accurate quotation information

Submit

*Please fill in the above fields (fields marked with an asterisk are required), and we will reply to your feedback as soon as possible.